Haydn boiler gas heating stove to warm the dedicated frequency L20BT trade | Обустройство дома



Сохраните в закладки:

Цена:RUB
*Стоимость могла изменится

Количество:


Новое поступление

Характеристики

Haydn boiler gas heating stove to warm the dedicated frequency L20BT trade | Обустройство дома

История изменения цены

*Текущая стоимость уже могла изменится. Что бы узнать актуальную цену и проверить наличие товара, нажмите "Добавить в корзину"

Месяц Минимальная цена Макс. стоимость Цена
Mar-20-2026 0.68 руб. 0.57 руб. 0 руб.
Feb-20-2026 0.24 руб. 0.74 руб. 0 руб.
Jan-20-2026 0.0 руб. 0.98 руб. 0 руб.
Dec-20-2025 0.45 руб. 0.26 руб. 0 руб.
Nov-20-2025 0.78 руб. 0.34 руб. 0 руб.
Oct-20-2025 0.7 руб. 0.59 руб. 0 руб.
Sep-20-2025 0.60 руб. 0.32 руб. 0 руб.
Aug-20-2025 0.39 руб. 0.64 руб. 0 руб.
Jul-20-2025 0.58 руб. 0.22 руб. 0 руб.

Описание товара

Haydn boiler gas heating stove to warm the dedicated frequency L20BT trade | Обустройство дома


How to use the gas boiler ?

◆ hot water / heating water heaters must be installed by a professional before using proper commissioning must be correctly installed random matching of smoke tube .
◆ technical parameters must use the type of gas specified on the hot water / heating water heaters.
◆ need an electrical outlet with a ground tripod sockets, plugs , sockets keep dry , can not water, beware of leakage . Do not touch the power line exhaust casing so as to avoid high temperature damage the insulation of the power cord .
◆ Make the required ground connection , not the ground or water connections and trachea .
◆ hot water / heating water heater should not be installed outdoors , in order to avoid the wind and rain , damage to the machine .
◆ heating system after installation , the system must be thoroughly cleaned , discharge debris to prevent damage to the hot water / heating water heater heating system .
◆ filling the heating system for the first time , please pay special attention to exclude air in the system , and pay attention to regular checks of water pressure in the system is in the normal operating range , open- check the fluid level is greater than 1/3.
Please note that mains phase (L, N) are correctly matched ◆ When connecting the power cord , or hot water / heating water heater does not work phenomenon occurs .
◆ hot water / heating water heater installed near the heating and water to avoid other wind to prevent the hot water / heating above the water heater due to wind and incomplete combustion occurs .
◆ Even cold winter without the use of hot water / heating water heaters, as well as to start the anti-freeze equipment , power outlet on the need , or the water heating system inside the net, and before turning off the power .
◆ In use, the first thing to note pressure must not be too high. 1.2 to 1.5 is the most suitable range will reduce over the life of the seal member , is too small does not start phenomenon occurs . The solution is to open the drain valve discouraged , open water switch water .
◆ bathing and washing dishes using a hot stove function . When we used to feel some of cold water blended with water and heat it , in fact, this is a misunderstanding, stove heated hot water is not directly come , so blended with cold water at the same time to change the pressure within the system cycle with hot , this pressure change will be passed to the appropriate circuits and chips from the sensing device , according to a preselected temperature furnace will rearrange the operating mode of each device , so repeat the operation will accelerate the aging of the device. Specific number of degrees the temperature setting should be based on the actual situation .
◆ If water is found in more and more hours out of water , we need to remove the water filter , to remove impurities .System Diagram

Boiler quiz

1 large boiler power it?
A: The main power boiler and turbine components are . The rated power boiler is generally between 110 ~ 160W. Different models , different power consumption .

2 , why domestic gas fireplaces are safe?
A: The gas boiler over 50 years history of use , technology is very mature in Europe , the reliable and effective security measures , absolutely safe operation.

3 , such as boiler pressure often decrease the need for frequent replenishment , whether hazardous ?
A : In this case , indicating the boiler or heating system for leaks site. First , water leakage can cause damage to property and, secondly, increasing the likelihood of boiler fouling , affecting the normal work , reduce service life .

4 , the boiler heating system pressure decreases because frequent downtime , requiring constant replenishment , how to respond?
A: Under normal circumstances, the pressure within the system should not be any major changes , that will not stop . As is often shut down, then there is the system tainted point, professionals boilers and heating system inspection and maintenance .

5, the boiler heating system scaling it happen ?
A: The boiler heating system connected should be a closed system . Heating system in one shot , you can use a long time. Due to less water , produce less , produce minimal scale , will not adversely affect the boiler and heating system .

6 , sanitary hot water and heating hot water boiler is a pipe inside it?
A: The hot water heating and sanitary hot water boiler in the heat exchanger has its own independent system , both absolutely can not mixing occurs .

7 , sleep see cooling equipment have?
A: The radiator , fan coil units , heaters, floor radiation.

8 , in order to freeze , can add antifreeze inside the boiler and heating system?
A: As long as antifreeze does not harm the boiler and heating system , you can use.
Boiler has a good freezing measures :
1 ) the home a short time ( one week ) when no one can be turned off boiler (but not power and gas cuts ) , or to put in antifreeze indoor location , if necessary , the boiler will automatically enter the freezing state. Boiler antifreeze only the local system , in order to ensure system security , it should determine a reasonable system design , the valve position is correct, so can we achieve the purpose of anti-freeze . Installation of boilers should be indoors, the minimum temperature above freezing .
2 ) long-term home when no one , should the boiler and heating system put in all the water clean. It must be noted that , prior to this operation please give full consideration to other indoor piping, such as water pipes will not freeze the election . Otherwise , let the boiler cool operation .

9. What are the benefits of using a coaxial flue ?
A: saving interior space and improve combustion efficiency.

10. What is the role of the fireplace in the expansion tank is ?
A: The amount of water absorption swelling within a closed heating system due to the temperature rise generated to keep the system pressure stable .

11. What are gas boiler safety protection device ?
A: thermal protection, water protection, fault protection combustion system over and undervoltage protection, anti- system resistance is too high, the intake and exhaust safety protection, frost protection, anti-lock , gas power, breathe , air pressure is too low self-locking protection dozen protection.

12 , the maximum capacity of the gas boiler heating system allows what factors determine ?
A: The temperature variation in the size of the expansion tank effective volume within the boiler , and the system determines the size of the largest interval water capacity.

13 , when the gas boiler work, how to breathe fresh air and flue gas emissions ?
A: The gas boiler at work , respectively, through the coaxial flue separate intake air intake pipe , exhaust pipe exhaust emissions. Both are separated from the indoor air environment , regardless of the indoor air environment , safe and reliable operation .

14 , four villas can use the gas boiler it?
A: The boiler is installed in a closed system, the pressure between 1 ~ 2bar, boiler built cycle just overcome resistance along the loop. So , as long as resistance at the design flow rate of the system will be provided in the product specification outer flow curve within the allowable range , the boiler can be used directly , or can refer equipment manufacturers to provide technical information to install an external circulation . This should be carefully considered ( in the boiler rated output power to meet the heating load of the premise of the villa ) . Boiler should be installed in a higher position , otherwise the boiler will lose a certain maximum capacity.

15 , when the winter heating , the boiler will be 24 hours of continuous job?
A: The basic is not , the size of the boiler output is greater value in accordance with the selection of sanitary hot water load . Design, the heating heat load must be considered certain temperature margin , so in the design room temperature , the boiler will automatically start and stop according to the set procedures , without human intervention. If the boiler has been in a low-power work , and does not stop, this time, the house is in thermal equilibrium at room temperature stable and comfortable.

16 , using a gas boiler bathing some benefits?
A: 1 ) large volume of water , a fireplace in country 23KW water temperature difference of 25 ° water production in case of 12L / min , could meet an upscale bath and a wash simultaneously.
2 ) hot water temperature stable . Always monitor the temperature of hot water temperature probe inside the boiler when water changes , the control panel automatically adjusts the boiler output power ( adjustment range of 30 % -100 %), hot water outlet temperature remains stable.

17 , gas consumption affect gas boiler heating What are the factors ?
A: The wall itself has no absolute relationship heating stove gas consumption and equipment, but mainly governed by the following factors :
1 ) indoor temperature setting ;
2 ) outdoor climatic conditions ;
3 ) ventilation ;
4 ) the impact floors ;
5 ) around the room occupancy rate ;
6) The user mode

18. What are the advantages of selecting the gas boiler have ?
A: 1 ) user per household as a system, while addressing the heating and hot water supply.
2 ) single-family heating gas boiler has a great adjustment flexibility , with full independence , the right to independently regulate the heating temperature , heating time can be controlled , the right freely to control the temperature of each room , boiler room and no external heat network of heat loss savings invested outside the network .
3 ) comply with the principles of charge on heat , and can accurately measure gas consumption , gas consumption by the user independent control , save gas .
4 ) low power consumption of the heating cycle , save energy , improve utilization and economic benefits of the gas pipeline .

19 , the end of European standard gas boiler and cooling package options?
A: The main consists of five major components : combustion systems , exhaust systems , heating and circulation systems , hot water systems, computer control system.

20 , the common gas boiler and cooling end supporting options?
A: The gas boiler with radiator systems , radiant floor systems , fan coil systems and so on ( Note : the system design , be sure to check the system flow , resistive , select the correct matching program ) .

21 , gas boiler can provide both heating and sanitary hot water it?
A: The European standard gas boiler heating and sanitary hot water mode can not run simultaneously, sanitary hot water priority function , gas boiler automatically switches according to the use of sanitary hot water in between the two .

22 , gas boiler has several operating modes , how to choose ?
A: The standard gas boiler provides heating and sanitary hot water two modes of operation . On the gas boiler control panel have winter / summer two options files, in winter gear , gas boiler provides heating and sanitary hot water function , sanitary hot water takes priority , so the user of sanitary hot water gas boiler use in the case of heating and sanitary hot water mode , automatic switching ; in the summer stalls , gas boiler is usually in standby mode, the user only in the case of sanitary hot water before entering the hot water mode. Therefore, the user can select the required heating during the winter season and the use of sanitary hot water stalls, the rest choose summer season , only sanitary hot water function .

23 , gas boiler can provide?
A: Usually gas boiler heating and hot water have two health functions.
But also only a part of the gas boiler heating function , which we call single-function system boiler (which is connected to an external hot water storage tank can also provide sanitary hot water ) .

24 , gas boiler can use what type of gas ?
A: natural gas, liquefied petroleum gas, professionals need to convert component replacement . Artificial gas boiler , use artificial gas .

25 , I often hear my sound of water inside the radiator ?
A: This may be the trapped air in the pipes or the radiator caused . You can turn on the heat to the top of the run outlet, the air inside let go , then , you have to adjust the heating boiler water pressure and ensure that the pressure is stable. This is achieved by the following water heating stove knob complete.

26 , in the shower , I have to wait a long time to get hot water !
A: No matter what your stove in working condition or how big your tank , the water retention time is determined by the amount of cold water in the pipes in the decision. Boiler itself from the ignition to the water for only a few seconds only.

27. Since the installation of the interior , radiators entire afternoon is cold ?
A: This is the benefit of using the device in the afternoon is a good time to stop working to make heating stove , plenty of light will let you maintain a comfortable room temperature .

28. Sometimes, when I open the hot water to the maximum water temperature seems low , it is not that so?
A: Yes, for as early as the second replaceable instant stove , the domestic hot water temperature depends on the velocity of the water . The faster the flow , the second plate exchanger for water heating function worse , when this happens, you can only reduce the flow of water can increase the temperature up .